Combined heat and power unit

CHP

Introduction and Model

The combined heat and power (CHP) unit utilizes sewage gas from the biogas storage to primarily generate electricity, which is used to power the aeration system of the activated sludge reactor. Additionally, the thermal energy produced during the process, which would otherwise be wasted, is recovered and utilized to maintain the necessary operating temperature of the anaerobic digester.

The CHP unit is implemented as a black box model, as its internal workings are not considered critical and are too complex to model in detail. The electrical and thermal power generation is calculated with defined efficiencies at the current utilization of the CHP unit. The biogas consumption of the CHP unit is calculated with the current utilization and the lower heating value of the biogas. The utilization rate \(k_{load}\) of the CHP is depended on the storage fill level of the biogas storage and can vary between a defined minimum utilization of 54% and 100%. The following cases are assumed:

  • Storage fill level (\(\gt\) 50%): CHP is fully utilized (\(k_{load} = 1\))

  • Storage fill level (\(\gt\) 35%): CHP is partially utilized (\(0.54 \ge k_{load} \lt 1\))

  • Storage fill level (\(\le\) 35%): CHP is not utilized (\(k_{load} = 0\))

To avoid sudden changes of the utilization, the CHP cannot adjust its utilization again for 6 hours after a change. Also, the CHP unit has a certain failure rate, after which a short maintenance break is required in order to be operational again.

Equations

Electrical and thermal power

\[ P_{el} = P_{gas,max} \cdot k_{load} \cdot \eta_{el}(k_{load}) \]
\[ P_{th} = P_{gas,max} \cdot k_{load} \cdot \eta_{th}(k_{load}) \]
Symbol Description Unit
\(P_{el}\) Electrical power generation kW
\(P_{th}\) Thermal power generation kW
\(P_{gas,max}\) Maximum gas uptake power kW
\(k_{load}\) Utilization rate of the CHP unit -
\(\eta_{el}(k_{load})\) Electrical efficiency at current utilization rate \(k_{load}\) -
\(\eta_{th}(k_{load})\) Thermal efficiency at current utilization rate \(k_{load}\) -

Biogas consumption

\[ \dot V_{gas} = \frac{P_{gas,max} \cdot k_{load}}{H_{u,gas}} \]
Symbol Description Unit
\(\dot V_{gas}\) Biogas consumption of the CHP unit Nm3 \(\cdot\) h-1
\(P_{gas,max}\) Maximum gas uptake power kW
\(k_{load}\) Utilization rate of the CHP unit -
\(H_{u,gas}\) Lower heating value of the biogas kWh \(\cdot\) Nm-3

Source code documentation

mod storage

mod storage_init